• 新闻
  • 联系SCHURTER
  • safe&easy
  • DE EN 中文
结果 out of 阅读更多 产品 查看所有结果

分享

分享此页面

您可以通过发送所选页面的URL与他人共享此页面。

Email LinkedIn
DC22 DC22 - IEC connector C14 with filter and Line switch 1- or 2-pole en IM0005197

Series: DC22

Free Sample Request

IEC Appliance Inlet C14 with Filter, Line Switch 1- or 2-pole, PCB Mounting

25 Variants


Connectors (Inlets/Outlets)

C14
Connector Logo
70° C

Description DC22

Description

  • Panel mount: Screw-on mounting on PCB from rear-side
  • 3 Functions: Appliance Inlet Protection class I, Line Switch 1  or 2 pole, Line filter in standard and medical version
  • For PCB mounting

Characteristics

  • Ultra-compact design
  • All single elements are already wired
  • Line switch non-illuminated or illuminated
  • With EMC-shield
  • Especially suitable for use in switching power supplies
    Ideal for application with high transient loads
  • Suitable for use in equipment according to IEC/UL 60950
    Suitable for use in medical equipment according to IEC/UL 60601-1

Other versions on request

  • Fixing on PCB with self-tapping screws 3 mm or pre-inserted nuts M3
  • Other rocker marking
  • Illuminated green
  • Medical version M80
  • Capacitance CX1

Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.

日期 子类别 语言 标题 下载
21/02/2019
产品彩页 英语 (English) Flyer Components and Solutions for Medical Equipment
04/02/2019
白皮书 英语 (English) White Paper Safety in medical Equipment
09/08/2018
产品彩页 英语 (English) Flyer V-Lock cord-retention safeguard
09/08/2018
白皮书 英语 (English) White Paper Cord retention
13/07/2018
PCN 英语 (English) All connectors PG06 PCN Change of configuration code PG06
06/04/2018
白皮书 英语 (English) White Paper Mating Connectors English
24/11/2017
白皮书 英语 (English) White Paper Leakage currents
09/09/2017
白皮书 英语 (English) White Paper Power Consumption
24/06/2016
证书 英语 (English) Tin Whisker Testing Report for KFA, DC22
20/04/2016
PCS 英语 (English) DC22 Product Content Sheet

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.
Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.

Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

25/085/21 acc. to IEC 60068-1

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.

The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.

Details about IP protection degree can be looked up in the general product information
IP-Protection

from front side IP40 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information

Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.

Detailed information about terminals can be looked up in the date sheet or in the general product information.
Terminal

For PCB mounting : Ground terminal: Quick connect terminals 6.3 x 0.8 mm angled to pin axis

Panel Thickness S

Panel Thickness S



See details in drawing
Snapper

Screw: max 4 mm
Mounting screw torque max 0.5 Nm

Material: Housing

Thermoplastic, black, UL 94V-0

appliance inlet/-outlet

appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information
Appliance Couplers
Mating Connectors
Term explanation
Special Connector Designs

C14 acc. to IEC 60320-1,
UL 498 CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I

Line Switch

Fuseholder


1.) fuse holder does not include circuit breakers

2.) Details about fuse-links can be found in the catalog under   Fuses

Detailed information on the fuse holder and fuse drawers can be found in the general product information.
Fuse drawer

Rocker switch 1 or 2 pole, non-illuminated or illuminated red, acc. to IEC 61058-1
Technical Details

Line Filter

Filter Type


Filter classification according leakage current for easy reading:

Standard: < 0.5 mA
Medical: < 0.1 mA

Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.
MTBF

> 2'100'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals

SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: DC22

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40001522
Approval marks cURus UL UL File Number: E72928


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Partners IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Partners IEC_Certification_Body Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Partners UL_Certification_Body Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Partners UL_Certification_Body Designed according to UL 1283 Electromagnetic interference filters
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
 V_Lock_Logo SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

预览
 

图片 选择产品图片可显示该类型的特定型号

型号
 

型号 对应于产品系列并包括各种不同型号。总结了有关类型的说明性数据,例如在数据表中

订单编号
 

订单编号 用于下达订单的唯一料号

配置键
 

配置键 产品的配置键由复合键值构成,这些值说明不同种类的属性特性。

注释
 
可能的焊盘图案,采用SMD安装
 

可能的焊盘图案,采用SMD安装 CAD 模型的简略说明

IGS
 

IGS 也称为 IGES(初始图形交换规范)。用于 3D CAD 数据的公共程序独立交换格式。

Step
 

Step 也称为 STEP(产品模型数据交换标准)。适用于按照 ISO 标准进行标准化的 3D CAD 数据的公共程序独立交换格式。

Parasolid
 

Parasolid 参数化实体建模内核是一种 3D CAD 系统。它由 Unigraphics Solutions (UGS)(现为 Siemens PLM Software)内的单独业务部门开发。

DXF
 

DXF (图形交换格式)是由 Autodesk 为 CAD 数据交换而指定的文件格式,专门为 2D-CAD 程序 AutoCAD 而开发。DXF 文件按照 ASCII 标准将 CAD 模型描述为纯文本。

DC22
DC22.1111.111 DC22.1121.111 DC22.1123.111 DC22.1221.111 DC22.1223.111 DC22.2111.111 DC22.2121.111 DC22.2123.111 DC22.2221.111 DC22.2223.111 DC22.4111.111 DC22.4121.111 DC22.4123.111 DC22.4221.111 DC22.4223.111 DC22.6111.111 DC22.6121.111 DC22.6123.111 DC22.6221.111 DC22.6223.111 DC22.9111.111 DC22.9121.111 DC22.9123.111 DC22.9221.111 DC22.9223.111
DC22.XXXX.XXX CAD-Model shows variation protection class I, 4 holes for screws M3, 2-pole rocker switch non-illuminated

Dimensions [mm]

Screw-on mounting

1) all pins
2) PE additionally as quick-connect terminal 6.3 x 0.8

Diagrams

Standard filter 1-pole

1) Line
2) Load
Standard filter 2-pole

1) Line
2) Load
Medical filter 1-pole (M5)

1) Line
2) Load
Medical version (M5)
2-pole
1) Line
2) Load
Standard filter 2-pole
illuminated
1) Line
2) Load
Medical Filter 2-pole (M5)
illuminated
1) Line
2) Load

Technical Data of Filter-Components

Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
1 Standard Version 2 x 10 100 2.2 1
2 Standard Version 2 x 4 100 2.2 1
4 Standard Version 2 x 1.5 100 2.2 1
6 Standard Version 2 x 0.8 100 2.2 1
10 Standard Version 2 x 0.3 100 2.2 1
1 Medical Version (M5) 2 x 10 100 - 1
2 Medical Version (M5) 2 x 4 100 - 1
4 Medical Version (M5) 2 x 1.5 100 - 1
6 Medical Version (M5) 2 x 0.8 100 - 1
10 Medical Version (M5) 2 x 0.3 100 - 1

Attenuation Loss

1 A

2 A

4 A

6 A

10 A

1 A

2 A

4 A

6 A

10 A


Short Table of Variants DC22 Open complete table DC22


Rated current

Rated current


Max. rated current according to IEC vs. UL/CSA- approval for the listed type.
Further details see data sheet

Filter-Type

Filter Type


Filter classification according leakage current for easy reading:

Standard: < 0.5 mA
Medical: < 0.1 mA

Line Switch

Line Switch


Also includes circuit breaker switch and switch for Bowden cables.

Details about the switches can also be found in the general product information.
Line Switch

Order Number

V-Lock


V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.

Details of the V-Lock system can be found in the general product information.
General Information V-Lock

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:
Contact-Form

Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check
Stock Check Distributor

...
[A]                
 
1 Standard Version 1-pole DC22.1111.111 ...
2 Standard Version 1-pole DC22.2111.111 ...
4 Standard Version 1-pole DC22.4111.111 ...
6 Standard Version 1-pole DC22.6111.111 ...
10 Standard Version 1-pole DC22.9111.111 ...
1 Standard Version 2-pole DC22.1121.111 ...
2 Standard Version 2-pole DC22.2121.111 ...
4 Standard Version 2-pole DC22.4121.111 ...
6 Standard Version 2-pole DC22.6121.111 ...
10 Standard Version 2-pole DC22.9121.111 ...
1 Standard Version 2-pole DC22.1123.111 ...
2 Standard Version 2-pole DC22.2123.111 ...
4 Standard Version 2-pole DC22.4123.111 ...
6 Standard Version 2-pole DC22.6123.111 ...
10 Standard Version 2-pole DC22.9123.111 ...
1 Medical Version (M5) 2-pole DC22.1221.111 ...
2 Medical Version (M5) 2-pole DC22.2221.111 ...
4 Medical Version (M5) 2-pole DC22.4221.111 ...
6 Medical Version (M5) 2-pole DC22.6221.111 ...
10 Medical Version (M5) 2-pole DC22.9221.111 ...
1 Medical Version (M5) 2-pole DC22.1223.111 ...
2 Medical Version (M5) 2-pole DC22.2223.111 ...
4 Medical Version (M5) 2-pole DC22.4223.111 ...
6 Medical Version (M5) 2-pole DC22.6223.111 ...
10 Medical Version (M5) 2-pole DC22.9223.111 ...
Alternative: version without line filter (1)

[Swipe to the left and right for more options]

Alternative: Standard version (1)

[Swipe to the left and right for more options]

Mating Outlets/Connectors (13)

[Swipe to the left and right for more options]

4787

4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I

4788

4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I

5091

IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal

4022

4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13

4782

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4012

4012 Mounting: Power Supply Cord, 3 x 1 mm², Screw clamps, Connector: IEC C13

4785

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4300-06

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4781

4781 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15

8101

8101 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C15

4784

4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15

4771

4771 Mounting: Power Supply Cord, 3 x 1 mm² / 3 x 14 AWG, Screw clamps, Connector: IEC C15A

4772

4772 Mounting: 3 x 1 mm² / 3 x 14 AWG, Screw clamps, Connector: IEC C15A

Mating Outlets/Connectors shuttered (1)

[Swipe to the left and right for more options]

VAC13KS

VAC13KS, Overview, V-Lock cord retaining, diverse Connector IEC C13, diverse, black

Accessories (2)

[Swipe to the left and right for more options]

Cord retaining kits

Cord retaining strain relief

4700.0008

Flat head, H


in.schurter.com
cns
cns
chi-CN
prod //cdn.schurter.com